Standard discharge connection
WebbRegulation 13 -. Standard discharge connection. To enable pipes of reception facilities to be connected with the ship's discharge pipeline for residues from machinery bilges and from oil residue (sludge) tanks, both lines shall be fitted with a standard discharge connection in accordance with the following table: 6 holes 22 mm in diameter ... WebbInternational Sewage Discharge Connection. The purpose of the International Sewage Connection is to enable pipes of reception facilities to be connected with the ship's …
Standard discharge connection
Did you know?
WebbeCFR Content § 158.250 Standard discharge connection. Each reception facility that received bilge water containing oily mixtures must have a standard discharge … http://marpoltraining.com/MMSKOREAN/MARPOL/Annex_IV/r11.htm
WebbRegulation 10 - Standard discharge connections 1 To enable pipes of reception facilities to be connected with the ship's discharge pipeline, both lines shall be fitted with a standard … Webb7 mars 2024 · In this regard, there are two types of standard discharge connections. This article mentions the specifications and requirements of this connections based on the …
WebbThe discharge connection must have the following dimensions: (1) Outside diameter = 215 millimeters (mm). (2) Inner diameter = according to pipe outside diameter. (3) Bolt circle diameter = 183 mm. (4) Slots in flange = 6 holes 22 mm in diameter equidistantly placed on a bolt circle of the above diameter, slotted to the flange periphery. Webbretaining oil residues. It shall not have any direct connection overboard, other than through the standard discharge connection, for discharging to a reception facility. (Reg. 12 and Interpretation 18) If chemicals are introduced in the discharges for circumventing the conditions of discharge then it shall not be hazardous to the environment.
WebbThese main inlet and discharge flange connections typically coincide with ASME/ANSI B16.1, B16.5, B16.42, or B16.47 series A or B as specified within the API 617 standard. Raised face (RF) flange designs are commonly used with either a flat gasket Fig. 3.30 or spiral wound gasket typically with a solid inner ring to prevent spiral wound gasket …
WebbWhat size are fire hydrant connections. A standard fire hydrant has two 2.5 inch- hose connection nozzles with 7.5 threads per inch, and one 4.5 inch-pumper connection nozzle with 4 threads per inch. The hose connection nozzle, compared to the pumper connection nozzle, has a lower discharge pressure and can be used directly to fight fires. twdfo.comWebb8 rader · Regulation 13 - Standard discharge connection: To enable pipes of reception facilities to be ... twd flagWebbDownload Table Standard dimensions of flanges for discharge connections by MARPOL 73/78 Annex IV requirements from publication: The Model to Assess the Implementation of Technical Conditions ... twd fivelWebbThe discharge connection must have the following dimensions: ( 1) Outside diameter = 215 millimeters (mm). ( 2) Inner diameter = according to pipe outside diameter. ( 3) Bolt … twd first seasonWebbSambungan pembuangan standar (Standard Discharge Connection) adalah saluran pipa pembuangan minyak kotor dari sludge tankke Reception Facilitiesyang ukuran dan bentuk sambungannya secara Internasional. g. Buku Pencatatan minyak (Oil Record Book) twd flannel charactersWebb31 aug. 2024 · Only oily mixture is allowed to be discharged provided they are filtered by oily water separator and follow the 15 ppm limit. For ships above 400 grt such discharge from engine room is permitted provided: … twd flare gun in mouthWebbRegulation 11 - Discharge of sewage. 1 Subject to the provisions of regulation 3 of this Annex, the discharge of sewage into the sea is prohibited, except when: .1. the ship is discharging comminuted and disinfected sewage using a system approved by the Administration in accordance with regulation 9.1.2 of this Annex at a distance of more … twd frank darabont